DFU stands for drainage fixture unit. This is a measure of probable fluid discharge into the drainage system by various types of plumbing fixtures. Each fixture’s DFU value depends on the volume of fluid discharge per cycle and an average time between cycles. The chart below gives you some examples of fixture DFU calculations. Always check with local building officials to confirm these calculations match theirs.                                                                                 Private Toilets (1.6 gpf) – 3 DFUs Public Toilets (1.6 gpf) – 4 DFUs Urinals (1 gpf or less) – 2 DFUs Shower (5.7 gpm or less) – 2 DFUs Kitchen Sink (domestic) with food grinder and / or dishwasher – 2 DFUs Laundry Sinks (1 or 2 compartments) – 2 DFUs Bathtub with or without overhead shower or whirlpool attachments – 2 DFUs Residential washing machine – 2 DFUs Commercial washing machines – 3 DFUs Bathroom Group 5 DFUs - consisting of 1-toilet (1.6 gpf), 1-lavatory sink, 1-bathtub or shower, including or excluding 1-bidet and 1-emergency floor drain. All fixtures in this group must be located on the same level. 
Sure-Vents come in 6 DFU capacity, 20 DFU capacity, 160 DFU capacity and 500DFU capacity.
The Sure-Vent should be installed a minimum of four inches above the horizontal branch drain (trap).
No. The AAV must have access to the open atmosphere. If the Sur-Vent is to be installed in a wall cavity, you must use one of our AAV wall boxes with a louvered face plate. This allows the Sure-Vent to have access to the open atmosphere, and also acts as an access door.
Yes, but the attic must have an access point for maintenance, and the valve should be installed at least six inches above the insulation. Extreme temperatures and insulation fibers can affect performance.
Yes, a Sure-Vent (air admittance valve) may be used to vent a sealed sump pit with a waste grinder pump, but only under certain conditions. Approval from local plumbing or building officials is required, as not all municipalities allow this application. It is also important to confirm compatibility with the pump manufacturer and ensure that all fixtures connected to the system are properly vented, since inadequate venting can lead to poor drainage and system performance issues. Because a Sure-Vent allows air into the system but does not relieve positive pressure, proper system design is critical. After confirming all approvals, you can contact customer service to request a detailed installation drawing for this setup.
Yes. The Sure-Vent is a mechanical device and like all mechanical devices, a scheduled maintenance routine should be set up to ensure AAV is functioning properly. 
No. Every dwelling needs to have one main vent stack exiting the roofline into the free atmosphere. It is also recommended that a relief vent be installed when completing a new home or large addition rough-in. 
No. Oatey Sure-Vents are not designed for exposure to ultraviolet rays and should not be installed outdoors.
DWV is an acronym used in the plumbing industry which means Drainage, Waste and Vents.