Cements, Primers & Cleaners Thread Sealants Copper Installation Putty, Caulks & Water Barriers Oils, Lubricants & Hand Cleaners Drain & Waste System Cleaners Heating Chemicals & Antifreeze Gaskets & Bolts Drains & Closet Flanges Shower Systems Supply Boxes Flashings Air Admittance Valves (AAV) Pipe Support Brass, Plastic & Commercial Tubular/Grab Bars Bath Waste & Overflow Baskets & Sink Strainers Pneumatic Test Balls Mechanical Test Plugs Testing Equipment / Tools & Accessories Pans & Stands Commercial Drains Rough-In Products
View All

Cherne Dearborn Harvey Hercules Keeney Oatey QuickDrain
View All

Commercial Plumbing Residential Plumbing Specialty Construction Waterworks
View All

Project Guides Videos Data Sheets (SDS) & Product Literature Product Catalogs FAQs Blog Case Studies BIM Revit 3 Part CSI, Master Spec ARCAT Blue Volt Training
View All

Oatey Brand Ambassadors Podcast Supplier Diversity Contact Us Subscribe
View All
About Careers Contact Us Where to Buy Select Region
< Flange Accessories

Oatey® Fix-it Flange Repair Ring

038753427751-01-01.jpg -
Oatey

The Oatey® Fix-it Repair Ring securely repairs broken, cracked or worn out toilet mounting flanges without replacing the toilet flange. The universal design fits all flange and toilet installations. Oatey products have earned the trust of plumbing professionals for over 100 years.

UPC: 038753427751
Part #: 42775


Key Features & Benefits

  • Fix-it ring repairs broken, cracked or worn out toilet flanges
  • Fits all flange and toilet installations
  • Works with all flooring types, including concrete
  • Engineered for secure connection to the floor
  • Mounting tabs fit under all toilets
  • Elongated slots allow for angled screws to grab flooring
  • Includes 10 mounting holes for a wide range of installation options
  • Perfect length bolt slot prevents bending during installation for secure, level and leak-free repairs
  • Accommodates 1/4 in. or 5/16 in. closet bolts
  • For warranty product details, refer to the Oatey Limited Warranty document

Specifications

Brand: Oatey
Color: Red
Material: Steel
Adjustable: Yes
Weight: 0.418 lb.

More Specifications

Technical Resources (4)

  • Submittal
  • FAQ
  • Product Instructions
  • Sell Sheet

More Downloads

Frequently Asked Questions

How do I install a Closet Flange Spacer Kit?

After the toilet has been removed, you must remove the existing toilet bolts and clean all the old wax off the existing toilet flange. Decide how much height is needed in order for the bottom of the top flange to be parallel with the finished floor height. You should replace the existing flange if it is broken or rusted badly; the spacer kit will not work for this application. After confirming the existing flange is in good condition, install the new extra-long toilet bolts into the flange. You can use the gaskets that come with the kit to seal between multiple PVC spacers, but 100% silicone is recommended between the top of the existing flange and the bottom of the first spacer. This will ensure that all voided areas are water tight between the transition points. After the desired height is reached, the flat washers and 1/4" nuts are threaded onto the extra-long bolts. This will compress and hold the spacers in place. It is recommended that you try and secure the new spacer or spacers to the subfloor through the four holes molded into the spacers. You can now install a wax seal and finish the toilet installation. Never use one of the seals in place of the wax seal. THE TOILET WILL LEAK WHEN FLUSHED!

Is there a flange that can be used to replace a broken or corroded cast iron flange for a toilet?

Oatey offers three styles of repair flanges for this application.  The first is the No-Caulk cast iron repair flange which comes in two depths. Once the old flange is removed and cast iron pipe is cleaned off, these flanges will slide over the vertical cast iron drain pipe. The flat side of the gasket should be facing down and resting on the inside bottom lip of the flange. Tightening the four bolts in even rotation will compress the gasket against the outside of the pipe, and create a water tight seal. Remember that the bottom of the flange must be set on top of the finished flooring, and then screwed into the subfloor. The second is our PVC or ABS Twist-N-Set repair flange which inserts into the vertical cast iron drain pipe after the old flange is removed. The gasket tightens as the flange is turned in a clockwise rotation. Remember that the bottom of the flange must be set on top of the finished flooring, and then screwed into the subfloor. The third option is the PVC or ABS Replacement closet repair flange which also inserts into the vertical cast iron drain pipe after the old flange is removed. This flange is sealed by the tightening of three stainless steel bolts in even rotation. This compresses the gasket between the outside of the flange tail piece, and the inside of the cast iron drain. Remember that the bottom of the flange must be set on top of the finished flooring, and then screwed into the subfloor. All flanges must be screwed into the subfloor before setting the toilet bowl into place, this sometimes will require drilling pilot holes through the finished flooring.      

When would a Closet Flange Spacer Kit be used?

The Closet Flange Spacer Kit is used when the finished floor of your bathroom is higher than the bottom of the existing toilet flange.

Related Resources

Blog

Five Best Practices when Installing a Toilet Flange

Read More
Video

How to Repair Broken Toilet Flange

View
View More

We use cookies to anonymously collect information about how you use our site, monitor site performance, and improve your experience.

By using our website you agree to these Terms of Use.

the choice of plumbing professionals
Oatey
Resources
FAQs Videos Blog Case Studies Plumbing Terms Data Sheets (SDS) & Product Literature BIM Revit CSI 3 Part Spec Oatey Limited Warranty ARCAT Catalogs Blue Volt Training
Company Info
Supplier Diversity Supplier Diversity About Us Oatey University Careers Idea Portal
Resources
FAQs Videos Blog Case Studies Plumbing Terms Blue Volt Training
Technical Resources
Data Sheets (SDS) & Product Literature BIM Revit CSI 3 Part Spec Oatey Limited Warranty ARCAT Catalogs
Company Info
About Us Oatey University Careers Supplier Diversity News & Press Idea Portal
Connect With Us

Contact Us

Patents | Trademarks | Supply Chain Information | Privacy and Terms of Use
© 2022 Oatey. All Rights Reserved.

It appears that you're using an unsupported browser.

If you are currently using Internet Explorer we recommend you switch to Edge or another supported browser to enjoy the best experience Oatey.com has to offer.

Learn More

OK